5.3.3. Cylindrical source

The parameters required for the cylindrical source type are given below. The order of the parameters is arbitrary. Parameters with (D=***) are optional.

Table 5.3.18 x0

value

explanation

(D=0.0)

x coordinate of the central axis of the cylinder source [cm].

Table 5.3.19 y0

value

explanation

(D=0.0)

y coordinate of the central axis of the cylinder source [cm].

Table 5.3.20 z0

value

explanation

(D=0.0)

Minimum z of the cylinder source [cm].

Table 5.3.21 z1

value

explanation

(D=0.0)

Maximum z of the cylinder source [cm]. When z1 = z0, this becomes a circular plane source.

Table 5.3.22 r0

value

explanation

(D=0.0)

Radius of the cylinder source [cm]. When r0 = 0.0, a pencil source results.

Table 5.3.23 r1

value

explanation

(D=0.0)

Inner radius of the cylinder [cm].

Table 5.3.24 dir

value

explanation

(D=1.0)

Direction cosine of the projectile relative to the z-axis.

all

Isotropic source.

data

An a-type subsection is required.

Table 5.3.25 phi

value

explanation

(D=all)

Azimuthal angle [degree].

all

Randomly selected in the range from 0 to 360 degrees.

Table 5.3.26 dom

value

explanation

(D=0.0)

Solid angle spread [degree].

-1

\(\cos^2\) bias distribution.

Table 5.3.27 e0

value

explanation

For mono-energy source, specify the projectile energy [MeV/n]. For an energy spectrum, use e-type = instead.

Table 5.3.28 e-type

value

explanation

mono-energy source

Give the source energy [MeV/n] directly by e0.

energy spectrum

Specify the source energy distribution by e-type.